Maxguard ML63-1 and ML100-1 RCCBs: order codes, 10mA and Type A options, and Malaysian prices

Maxguard’s residual current circuit breakers (RCCBs, often still called ELCBs) are the ML63-1 series, for 25–63A, and the ML100-1 for 100A. They trip on earth leakage and give no overload protection, so they always sit with MCBs. The table lists every code in Maxguard’s catalogue.

Maxguard ML63-1 and ML100-1 RCCBs

Residual-current circuit breakers offered in 25A, 40A and 63A ML63-1 variants and a 100A ML100-1 family. The manufacturer lists Type AC and Type A options; the family name alone does not identify the waveform type.

Families
ML63-1 (25A/40A/63A) and ML100-1 (100A)
Manufacturer-listed sensitivity options
10, 30, 100 and 300mA
Manufacturer-listed waveform options
Type AC (order-code suffix N) and Type A (suffix A); the family name alone does not identify the waveform type
Order codes 2P Type AC
E40203N (40A 30mA), E40210N (40A 100mA), E63203N (63A 30mA), E63210N (63A 100mA), E40230N (40A 300mA), E63230N (63A 300mA), E25201N (25A 10mA)
Order codes 2P Type A
E40203A (40A 30mA), E40210A (40A 100mA), E63203A (63A 30mA), E63210A (63A 100mA)
Order codes 4P Type AC
E40403N/E40410N (40A), E63403N/E63410N (63A), E40430N/E63430N (40A/63A 300mA); no Type A 4P 300mA in catalogue
Order codes 4P Type A
E40403A (40A 30mA), E40410A (40A 100mA), E63403A (63A 30mA), E63410A (63A 100mA)
Order codes ML100-1 4P Type AC
E100403N (100A 30mA), E100410N (100A 100mA), E100430N (100A 300mA)
Technical data
IEC 61008-2-1; 230/400V~, 240/415~; 50/60Hz; conditional surge current proof 3000A 8/20µs; rated conditional short-circuit breaking capacity Icn 10kA with 10kA back-up fuse; Icm 500A or 10In; IP20; pollution degree 3; >2000 operating cycles
Widths and terminals
2P = 2 module/36mm, 4P = 4 module/72mm; ML63-1 terminal 1–25mm², ML100-1 1–35mm²; DIN rail EN 50022
Catalogue breaking capacity note
The 10kA figure is a conditional short-circuit rating that assumes a 10kA back-up fuse — it is not a stand-alone breaking capacity like an MCB's Icn
Standard (catalogue)
IEC 61008-2-1; conditional surge current proof 3000 A 8/20 µs ('anti nuisance tripping'); conditional short-circuit 10 kA with 10 kA back-up fuse
Width (catalogue)
2P 36 mm (2 modules), 4P 72 mm
Selected variants
ModelConfigurationReference item price
E40203NML63-1, 2P, 40 A, 30 mA, Type AC—
E40210NML63-1, 2P, 40 A, 100 mA, Type AC—
E63203NML63-1, 2P, 63 A, 30 mA, Type AC—
E63210NML63-1, 2P, 63 A, 100 mA, Type AC—
E40230NML63-1, 2P, 40 A, 300 mA, Type AC—
E63230NML63-1, 2P, 63 A, 300 mA, Type AC—
E25201NML63-1, 2P, 25 A, 10 mA, Type ACRM91.40
E40203AML63-1, 2P, 40 A, 30 mA, Type A—
E40210AML63-1, 2P, 40 A, 100 mA, Type A—
E63203AML63-1, 2P, 63 A, 30 mA, Type A—
E63210AML63-1, 2P, 63 A, 100 mA, Type A—
E40403NML63-1, 4P, 40 A, 30 mA, Type AC—
E40410NML63-1, 4P, 40 A, 100 mA, Type AC—
E63403NML63-1, 4P, 63 A, 30 mA, Type AC—
E63410NML63-1, 4P, 63 A, 100 mA, Type AC—
E40430NML63-1, 4P, 40 A, 300 mA, Type AC—
E63430NML63-1, 4P, 63 A, 300 mA, Type AC—
E40403AML63-1, 4P, 40 A, 30 mA, Type A—
E40410AML63-1, 4P, 40 A, 100 mA, Type A—
E63403AML63-1, 4P, 63 A, 30 mA, Type A—
E63410AML63-1, 4P, 63 A, 100 mA, Type A—
E100403NML100-1, 4P, 100 A, 30 mA, Type AC—
E100410NML100-1, 4P, 100 A, 100 mA, Type AC—
E100430NML100-1, 4P, 100 A, 300 mA, Type AC—
Sources

Reading the code

The code gives the rating, poles, sensitivity and type. Take E40203N:

  • E40: 40A
  • 2: 2-pole (4 means 4-pole)
  • 03: 30mA (01 is 10mA, 10 is 100mA, 30 is 300mA)
  • N: Type AC (a final A means Type A)

The ML100-1 codes start E100. This is our reading of the catalogue table, so confirm on the product.

What the catalogue says

From Maxguard’s catalogue (March 2022 edition, the one its website links to):

  • Standard: IEC 61008-2-1, the standard for RCCBs that work independently of line voltage.
  • Trip time: undelayed (under 100ms).
  • Short-circuit rating: 10kA conditional, with a 10kA back-up fuse.
  • Width: 36mm for 2-pole and 72mm for 4-pole.
  • Surge withstand: rated for a 3000A 8/20µs surge without tripping, which the catalogue calls “anti nuisance tripping”.
  • Warranty: 60 months (terms apply).

The options are uneven:

  • 10mA: only one model, E25201N (2P 25A Type AC), for water-heater circuits. With an MCB of 25A or less, it suits heaters up to about 4.46kW under the Energy Commission’s water-heater table.
  • Type A: only at 30 and 100mA, in 40 and 63A.
  • ML100-1: 100A 4-pole, Type AC only.

For a Type A 10mA device from Maxguard, look at the ML32-1 RCBO instead. Our water heater guide explains the 10mA rule and the 2-pole requirement.

Prices in Malaysia

ene2u, a Malaysian online shop, lists:

ModelPrice
E25201N, 2P 25A 10mARM91.40
ML63-1 2P 40A 30mARM66.60 (was RM99.20)
ML100-1 4P 100A 30mARM300 (was RM386)
ML100-1 4P 100A 100mARM285
ML100-1 4P 100A 300mARM255.90

KVC, a Malaysian electrical distributor, also lists E25201N, with prices for signed-in accounts, and Maxguard RCCBs are widely sold on Shopee and Lazada. Order by the exact code, since “ELCB 25A 10mA” listings don’t always say whether a device is Type AC or Type A.