Products · Malaysia
Hager RCCBs in Malaysia: the four 10mA models, Type A vs AC, "2P" vs "1P+N", and prices
An RCCB (residual current circuit breaker, often still called an ELCB) trips when current leaks to earth. It has no overload or short-circuit protection of its own, so it always works with MCBs. In Malaysian homes the question is usually which 10mA device to put on the water-heater circuit. The rule (Electricity Regulations 1994, regulation 36(2), and the Energy Commission’s water-heater guideline GP/ST/No.6/2016) is leakage protection of 10mA or less, from either an RCBO or an RCCB plus MCB. Hager Malaysia’s FAQ puts it in terms of its own products: “it is mandatory to install 10mA RCCB for water heater protection”, at the distribution board and used only for the water heater.
As of 6 October 2026, Hager Malaysia’s RCCB category lists 63 RCCBs: 4 at 10mA, 25 at 30mA, 17 at 100mA, 14 at 300mA and 3 at 500mA, from 16A to 100A. The table shows the four 10mA models, the common 2-pole and 4-pole 30mA models and two 100mA models, followed by the 20 RCCB pages Hager Malaysia keeps outside the category, each marked obsolete, spare part or phase out.
Hager RCCBs (Malaysia)
Hager residual current circuit breakers on Hager Malaysia's catalogue: 63 references from 16A to 100A at 10, 30, 100, 300 and 500mA, in Type AC, Type A, high-immunity and time-delayed versions. Four are 10mA; the table shows those, the common 2-pole and 4-pole 30mA models and two 100mA models, then the 20 RCCB pages Hager Malaysia keeps outside the category, each marked obsolete, spare part or phase out.
- Malaysian list
- 63 RCCBs in Hager Malaysia's RCCB category: 10mA ×4, 30mA ×25, 100mA ×17, 300mA ×14, 500mA ×3
- 10mA models
- CC216B (2P 16A Type AC), CC225B (2P 25A Type AC), CCA225B (1P+N 25A Type A), CCA540D (1P+N 40A Type A); CCA525D (1P+N 25A Type A) has a Hager Malaysia page marked Obsolete
- Off-list pages
- 20 RCCB pages outside the category: 9 obsolete, 9 spare part, 2 phase out. 10mA: CCA525D only. 30mA: CD216J, CDA580D, CDH225J. 100mA: CEA640D, CEC680B, CNA263N. 300mA: CF225B, CF425B, CFA680D, CFC580B, CFC680B, CP440B, CPC263M, CQ240J, CQ440J. 500mA: CG225B, CG240B, CG425B, CG440B
- Poles
- Hager titles say 2P or 1P+N for the same 2-pole, 2-module design (its spec tables give 2 poles for both); 4P titles are 3P+N, 4 poles
- Residual types
- Type AC (codes ending B, except CCA225B, which is Type A), Type A (J and D), Type A high immunity (CDH, CH, CQ), time-delayed S (CN, CP, CPA; off-list CNA and CPC)
- Conditional short-circuit current (Inc)
- 10kA for Type AC CC/CD/CE/CF/CG…B and the D-suffix Type A series; 6kA for J-suffix Type A, high-immunity and CCA225B; 6kA for the off-list time-delayed CNA263N and CPC263M
- Widths
- 2-pole 35 or 36mm (2 modules); 4-pole 70 or 72mm
- Standards in linked documents
- EN 61008-1 on all datasheets; the EU declaration for CCA540D and the listed CDA/CEA/CFA 5xx/6xx D models also lists EN/IEC 61008-2-1 (voltage-independent); the declaration for the CC/CD/CE…B/J series lists EN 61008-1 only
- Also on Hager Malaysia
- RCCB with auto recloser: CDA240SC and CDA263SC (1P+N 40/63A 30mA Type A, 3 modules)
| Model | Configuration |
|---|---|
| CC216B | RCCB, 2P (2 poles switched), 16 A, 10 mA, Type AC |
| CC225B | RCCB, 2P (2 poles switched), 25 A, 10 mA, Type AC |
| CCA225B | RCCB, 1P+N (2 poles switched), 25 A, 10 mA, Type A |
| CCA540D | RCCB, 1P+N (2 poles switched), 40 A, 10 mA, Type A |
| CCA525D | RCCB, 1P+N (2 poles switched), 25 A, 10 mA, Type A — Obsolete on Hager Malaysia |
| CD216B | RCCB, 2P (2 poles switched), 16 A, 30 mA, Type AC |
| CD225B | RCCB, 2P (2 poles switched), 25 A, 30 mA, Type AC |
| CD240B | RCCB, 2P (2 poles switched), 40 A, 30 mA, Type AC |
| CD240J | RCCB, 2P (2 poles switched), 40 A, 30 mA, Type A |
| CD263B | RCCB, 2P (2 poles switched), 63 A, 30 mA, Type AC |
| CD263J | RCCB, 2P (2 poles switched), 63 A, 30 mA, Type A |
| CDA525D | RCCB, 1P+N (2 poles switched), 25 A, 30 mA, Type A |
| CDA540D | RCCB, 1P+N (2 poles switched), 40 A, 30 mA, Type A |
| CDA563D | RCCB, 1P+N (2 poles switched), 63 A, 30 mA, Type A |
| CDH240J | RCCB, 2P (2 poles switched), 40 A, 30 mA, Type A (high immunity) |
| CH263J | RCCB, 2P (2 poles switched), 63 A, 30 mA, Type A (high immunity) |
| CE240B | RCCB, 2P (2 poles switched), 40 A, 100 mA, Type AC |
| CE263B | RCCB, 2P (2 poles switched), 63 A, 100 mA, Type AC |
| CD440B | RCCB, 4P, 40 A, 30 mA, Type AC |
| CD440J | RCCB, 4P, 40 A, 30 mA, Type A |
| CD463B | RCCB, 4P, 63 A, 30 mA, Type AC |
| CD463J | RCCB, 4P, 63 A, 30 mA, Type A |
| CD216J | RCCB, 2P (2 poles switched), 16 A, 30 mA, Type A — Obsolete on Hager Malaysia |
| CDA580D | RCCB, 1P+N (2 poles switched), 80 A, 30 mA, Type A — Obsolete on Hager Malaysia |
| CDH225J | RCCB, 2P (2 poles switched), 25 A, 30 mA, Type A (high immunity) — Spare part on Hager Malaysia |
| CEA640D | RCCB, 3P+N (4 poles switched), 40 A, 100 mA, Type A — Spare part on Hager Malaysia |
| CEC680B | RCCB, 3P+N (4 poles switched), 80 A, 100 mA, Type AC — Spare part on Hager Malaysia |
| CF225B | RCCB, 2P (2 poles switched), 25 A, 300 mA, Type AC — Obsolete on Hager Malaysia |
| CF425B | RCCB, 4P, 25 A, 300 mA, Type AC — Phase out on Hager Malaysia |
| CFA680D | RCCB, 3P+N (4 poles switched), 80 A, 300 mA, Type A — Spare part on Hager Malaysia |
| CFC580B | RCCB, 1P+N (2 poles switched), 80 A, 300 mA, Type AC — Spare part on Hager Malaysia |
| CFC680B | RCCB, 3P+N (4 poles switched), 80 A, 300 mA, Type AC — Obsolete on Hager Malaysia |
| CG225B | RCCB, 2P (2 poles switched), 25 A, 500 mA, Type AC — Obsolete on Hager Malaysia |
| CG240B | RCCB, 2P (2 poles switched), 40 A, 500 mA, Type AC — Spare part on Hager Malaysia |
| CG425B | RCCB, 4P, 25 A, 500 mA, Type AC — Obsolete on Hager Malaysia |
| CG440B | RCCB, 4P, 40 A, 500 mA, Type AC — Spare part on Hager Malaysia |
| CNA263N | RCCB, 2P (2 poles switched), 63 A, 100 mA, Type A (time-delayed S) — Obsolete on Hager Malaysia |
| CP440B | RCCB, 4P, 40 A, 300 mA, Type AC (time-delayed S) — Spare part on Hager Malaysia |
| CPC263M | RCCB, 2P (2 poles switched), 63 A, 300 mA, Type AC (time-delayed S) — Phase out on Hager Malaysia |
| CQ240J | RCCB, 2P (2 poles switched), 40 A, 300 mA, Type A (high immunity) — Obsolete on Hager Malaysia |
| CQ440J | RCCB, 4P, 40 A, 300 mA, Type A (high immunity) — Spare part on Hager Malaysia |
Sources
- Hager Malaysia – RCCB category
- Hager Malaysia – FAQ, energy distribution
- Hager Malaysia leaflet – RCCB Type A with 10kA Inc (MY-2021_07)
- Hager EU declaration 26.2118 – standard RCCBs 16/125A (linked from Hager Malaysia pages)
- Hager EU declaration 26.1690 – RCCBs 16/63A (linked from Hager Malaysia pages)
- Edaran – Hager category
- Hager Malaysia – CC216B
- BigGo Malaysia – hager rccb 10mA
- Hager Malaysia – CC225B
- KVC – Hager CC225B
- BigGo Malaysia – hager CC225B
- Hager Malaysia – CCA225B
- Edaran – Hager CCA225B
- BigGo Malaysia – hager CCA225B
- Hager Malaysia – CCA540D
- Hager Malaysia – CCA525D
- Hager Malaysia – CD216B
- Hager Malaysia – CD225B
- Hager Malaysia – CD240B
- Hager Malaysia – CD240J
- BigGo Malaysia – hager CD240J
- Hager Malaysia – CD263B
- Hager Malaysia – CD263J
- Hager Malaysia – CDA525D
- Hager Malaysia – CDA540D
- BigGo Malaysia – hager CDA540D
- Hager Malaysia – CDA563D
- Hager Malaysia – CDH240J
- Hager Malaysia – CH263J
- Hager Malaysia – CE240B
- Hager Malaysia – CE263B
- Hager Malaysia – CD440B
- Hager Malaysia – CD440J
- Hager Malaysia – CD463B
- Hager Malaysia – CD463J
- Hager Malaysia – CD216J
- Hager Malaysia – CDA580D
- Hager Malaysia – CDH225J
- Hager Malaysia – CEA640D
- Hager Malaysia – CEC680B
- Hager Malaysia – CF225B
- Hager Malaysia – CF425B
- Hager Malaysia – CFA680D
- Hager Malaysia – CFC580B
- Hager Malaysia – CFC680B
- Hager Malaysia – CG225B
- Hager Malaysia – CG240B
- Hager Malaysia – CG425B
- Hager Malaysia – CG440B
- Hager Malaysia – CNA263N
- Hager Malaysia – CP440B
- Hager Malaysia – CPC263M
- Hager Malaysia – CQ240J
- Hager Malaysia – CQ440J
The four 10mA models
| Code | Hager’s title | Rating | Type | Inc | Width |
|---|---|---|---|---|---|
| CC216B | RCCB 2P 16A 10mA AC | 16A | AC | 10kA | 35mm |
| CC225B | RCCB 2P 25A 10mA AC | 25A | AC | 10kA | 35mm |
| CCA225B | RCCB 1P+N 25A 10mA A | 25A | A | 6kA | 35mm |
| CCA540D | RCCB 1P+N 40A 10mA A | 40A | A | 10kA | 36mm |
All four are 230V, 2-module devices. Inc is the conditional short-circuit current to EN 61008-1, the fault level the RCCB withstands when it’s protected by suitable upstream devices; it is not a breaking capacity like an MCB’s.
Hager Malaysia also has a page for CCA525D (1P+N 25A 10mA Type A), but it’s marked Obsolete, and it isn’t in the category list. It’s the only 10mA RCCB among the pages Hager Malaysia keeps outside the category. If a seller offers it, it may be old stock.
Which rating? The Energy Commission’s water-heater guideline (GP/ST/No.6/2016) sets minimum MCB/RCD ratings by heater power at 230V: 16A below about 2.86kW, 20A to about 3.57kW, 25A to about 4.46kW and 32A to about 5.71kW. The RCCB’s current rating should be at least that of the MCB protecting the heater circuit. CC216B suits the small range; CC225B and CCA225B cover most home heaters with a C20 or C25 MCB; CCA540D is the only 10mA Hager RCCB above 25A, for 32A or 40A heater circuits. Our water heater guide has the full table and cable sizes.
“2P” or “1P+N”?
Hager’s titles call CC225B “2P” and CCA225B “1P+N”, but they’re the same kind of device. Both product pages list “Type of pole: 1P+N” and “Number of poles: 2”: live and neutral both pass through the RCCB, and it disconnects both when it trips. (The 4-pole models are listed the same way, as “3P+N” with 4 poles.)
That matters because the water-heater guideline’s single-phase scheme calls for a 2-pole RCD. Each of Hager’s four 10mA RCCBs is a 2-pole device by Hager’s own specification, whichever label is in the title.
Type A or Type AC?
Type AC detects ordinary alternating leakage current. Type A also detects pulsating DC leakage, which some electronic controls can produce. Hager Malaysia’s leaflet for its Type A RCCBs says they respond “to the different types of sinusoidal alternating residual currents and pulsating direct residual currents” and are used where loads run “without frequency converters or rectifiers”; its FAQ calls Type A “suitable for equipment with electronic components”. The Energy Commission’s domestic wiring guide notes that Type AC is the most common in homes and encourages Type A where there’s a lot of electronic equipment.
At 10mA, Hager’s Type A options are CCA225B (25A) and CCA540D (40A). Read the code carefully: CC225B and CCA225B differ by one letter. Some Malaysian listings mix them up; one titled “CCA225B … TYPE A” gives “CC225B” as the model in its description.
Voltage-independent?
Some Malaysian electricians prefer voltage-independent RCDs, which don’t need mains voltage to trip, and check the standard on the datasheet: IEC/EN 61008-2-1 means voltage-independent and 61008-2-2 means voltage-dependent. Hager Malaysia’s product pages and datasheets cite only EN 61008-1 and don’t use either term. The EU declarations of conformity linked from those pages go a little further:
- The declaration covering CCA540D and Hager Malaysia’s listed CDA/CEA/CFA 5xx/6xx “D” Type A models lists EN/IEC 61008-2-1, the voltage-independent standard. Other “D” codes that aren’t on Hager Malaysia’s site, such as CDA240D and CDA263D, fall under a declaration that lists EN 61008-1 only.
- The declaration covering CC216B, CC225B and CCA225B (with the CD, CE and CF “B” and “J” models) lists EN 61008-1 only, which doesn’t settle it either way.
So CCA540D is the one 10mA Hager RCCB whose linked documents name the voltage-independent standard. For the other three, ask Hager Malaysia or the supplier. An EU declaration is a European conformity document, not the ST-SIRIM approval required in Malaysia; check the ST-SIRIM label on the unit.
The rest of the list
- 30mA, 2-pole: CD216B, CD225B, CD240B and CD263B (Type AC, Inc 10kA); CD240J and CD263J (Type A, 6kA); CDA525D, CDA540D and CDA563D (Type A, 10kA, 36mm). CD240J is a 40A Type A unit.
- High immunity (HI): CDH240J and CH263J (30mA), CQ263J (300mA) and their 4-pole versions are Type A RCCBs; Hager describes its HI types as having “increased resistance to nuisance tripping”.
- Time-delayed (S): CN240B, CN440B, CN463B, CP463B and CPA684D, for upstream use where downstream RCDs should trip first.
- 4-pole for three-phase: from 25A to 100A, at 30, 100, 300 and 500mA.
- Pages outside the category: Hager Malaysia’s product index, the search index behind its site, has 20 more RCCB pages that the category doesn’t list: 9 marked Obsolete, 9 Spare part (“check availability with your electrical wholesaler”) and 2 Phase out (checked 8 October 2026). Besides CCA525D they include 30mA CD216J, CDA580D and CDH225J, the time-delayed CNA263N, CP440B and CPC263M, and the 500mA CG225B, CG240B, CG425B and CG440B. The product table at the top of the page lists each with its status. Hager doesn’t list them in its current range, though a wholesaler may still have stock.
- Older codes: CDA240D, a 2P 40A 30mA Type A model that appears on Hager’s European datasheets, has no Hager Malaysia page at all, not even one marked obsolete, and we didn’t find a Malaysian listing for it; the comparable listed model is CD240J. Older stock may still turn up, so check its rating against the label.
- Auto-reclosing RCCBs: a separate Hager Malaysia category lists CDA240SC and CDA263SC (1P+N 40A and 63A, 30mA Type A, 3 modules), designed to switch back on after a transient trip.
Prices in Malaysia
These are listed prices on 6 October 2026, from a Malaysian shop site and from Shopee and Lazada stores via BigGo Malaysia. A listing isn’t confirmed stock, and we haven’t examined the products.
| Model | Listed prices |
|---|---|
| CC225B, 2P 25A 10mA AC | RM196.10–253.65 at four stores: N.A Engineering (Selangor, sold out), Pentagon Electric Mart (Selangor), Combi Electric (Johor), FOCUS Electrical (Pahang) |
| CCA225B, 1P+N 25A 10mA Type A | RM167.20 (Edaran on Lazada), RM196.30 (Edaran’s own site and Shopee), RM215 (Pentagon), RM320 (CPE Electrical, Penang) |
| CC216B, 2P 16A 10mA AC | RM243.60–330 at five stores: Hoe Electrical Service, Nicetomiyou (Perak), Howon Exin Venture (Perak, sold out), Pentagon, CPE; Combi Electric’s RM225.90 listing covers both CC216B and CC225B |
| CDA540D, 1P+N 40A 30mA Type A | RM452 (Pentagon) |
| CD240J, 2P 40A 30mA Type A | RM207 (Pentagon) to RM259 (CPE) |
One store lists CC225B at RM115 and CD240J at RM135, far below the others; compare carefully before relying on outliers. A BigGo search for CCA540D (10mA) found no listings.
Compared with Schneider and Maxguard at the same rating, 2-pole 25A 10mA:
- Schneider Easy9 EZ9R14225 (Type AC): RM100–121.53 on Shopee; EZ9R26225 (Type A): RM100 in one listing.
- Maxguard E25201N (Type AC): RM91.40 at ene2u.
- Hager CC225B (Type AC): RM215–253.65 in listings not marked sold out; CCA225B (Type A): RM167.20–320.
The same store, Pentagon Electric Mart, lists Hager CC225B at RM215 and Schneider EZ9R14225 at RM100. Comparing like with like, Hager’s Type AC CC225B costs about 1.8–2.5 times Schneider’s EZ9R14225 and 2.4–2.8 times Maxguard’s E25201N, and its Type A CCA225B about 1.7–3.2 times the one EZ9R26225 listing. The ratings aren’t identical: Hager’s CC225B has a 10kA conditional short-circuit rating, against 4.5kA for EZ9R14225. Maxguard has no 10mA Type A RCCB; its Type A 10mA option is the ML32-1 RCBO.
Where to find them
Edaran (Edaran Eleknas Sdn Bhd), 29 Jalan 14/108C, Taman Sungai Besi, Kuala Lumpur, lists CCA225B at RM196.30 and a Hager category with 2-pole and 4-pole RCCBs. It’s open Monday to Friday 8.30am–5pm and Saturday 8.30am–1pm, on +03-7980 0398.
KVC, an electrical distributor, lists CC225B and shows prices only to signed-in accounts.
Win Mah in Air Itam, Penang (+6012-493 9412), has an enquiry page for Hager 2-pole RCCBs with 16A and 25A 10mA options.
On Shopee and Lazada, Pentagon Electric Mart, Edaran, Combi Electric and CPE Electrical list several of these codes. One electrician in a Malaysian wiring group noted that Hager is sold only by some shops (what electricians say about breaker brands), so ask your usual supplier before assuming a code is available. Order by the full code, and check the ST-SIRIM label on the unit.
For an RCBO instead of an RCCB plus MCB, see Hager RCBOs: Hager Malaysia’s current RCBO list has no 10mA model.